gas powered suction stop valve

32 Comments

gas powered suction stop valve

109240 Parker - Refrigerating Specialties 4 CK-6D-DN S6B

109240 Parker - Refrigerating Specialties 4 CK-6D-DN S6B Dual Position Gas Powered Suction Stop Valve.Be the first to review this product .The CK-6D is a suction stop valve for hot gas defrost applications.was $2,809.98 Special Price $2,675.98.SKU# 109240.Manufacturer:CK5A1XS13WP1X0NSN - Gas Powered Suction Stop Valve-The CK-5 gas-powered suction stop valve provides the normal operating features of the R/S CK-2 suction stop valve and features a built-in failsafe to close the valve until pressure isDual Position Gas Powered BULLETIN 50-25B Suctiongas-powered suction stop valves for low temperature evaporators.Because of the return spring,there is no line pressure drop required to open the valve during refrigeration.This allows for a minimal pressure drop November 2006 Installation,Service and Parts Information 311447 ISO 9001 - 2 0 0 0 CERTIFIED Solenoid #2 Solenoid #1 Primary Piston Secondary

Dual Position Gas Powered Bulletin 50-25C Suction Stop

gas-powered suction stop valves for low temperature evaporators.Because of the return spring,there is no line pressure drop required to open the valve during refrigeration.This allows for a minimal pressure drop penalty in the suction line.The CK-6D will positively close theDual Position Gas Powered Suction Stop ValveThese valves are employed as a low pressure drop,gas-powered suction stop valve for low temperature evaporators.Because of the return spring,there is no line pressure drop required to open the valve during refrigeration.This allows for a minimal pressure drop penalty in the suction line.Dual PositionGas Powered BULLETIN 50-24b SuctionThese valves are employed as a low pressure drop,gas-powered suction stop valve for low temperature evaporators.Because of the return spring,there is no line pressure drop required to open the valve during refrigeration.This allows for a minimal pressure drop penalty in the suction line.The CK-2D will positively close the suction line

File Size 1MBPage Count 8Gas Powered Suction Stop Valves- Ck-2D - Clark Johnson Co

Jun 09,2019·The CK-2D valves are employed as a low pressure drop,gas-powered suction stop valve for low temperature evaporators.These valves are used for suction stop and evaporator equalization following a defrost cycle.File Size 559KBPage Count 8Parker Valve StationSuction Stop Valve 80 3 Relief Regulator Suction Regulator Hot Gas Defrost High Pressure Liquid Full 35% 86.5 30.3 100.0 35.0 21 2 SW 21 2,3 BW 65,80 54 - 60 120 - 132 Pumped Liquid Feed Suction Stop Valve 1.The flow coefficient shown is for the control module in position three shown in Figure 1.2.The weight will vary based on the GAS POWERED B SUCTION STOP VALVE - Parker HannifinThe purpose of the CK-5 gas-powered suction stop valve is to provide the normal operating features of the R/S CK-2 stop valve.In addition,this unique control valve incorporates a built-in mechanical fail-safe feature which prevents the undesirable effects of an immediate opening of the valve in

GAS POWERED SUCTION STOP VALVE - Parker Hannifin

Along with the standard R/S type CK-2 gas-powered suction stop valve,the CK-5 is typically used for low temperature applications in wet return lines on liquid recirculation systems or on the liquid and gas return legs of ooded evaporators.Due to its normally open construction,pressure drop is minimal in suction or wet return applications.GAS POWERED SUCTION STOP VALVE - Parker HannifinGAS POWERED SUCTION STOP VALVE Type CK-2 Port Size 32mm to 150mm (1¼ - 6) Purpose These special valves are used on low temperature applica-tions to positively close suction lines and both liquid legs and gas returns on flooded evaporators.Because of the spring,no line pressure drop is required to open the valve;Gas Powered Suction Stop Valve - RefrigerationTh e CK-2W gas powered suction stop valves are an integrated assembly of two modules 1.A body,which contains the modulating plug,but is ordered to suit a particular connection size.Th e port size defi nes the size of the body; 2.A port plate,which contains

Gas Powered Suction Stop Valve- CK-5 - Clark Johnson Co

Jun 09,2019·The CK-5 gas-powered suction stop valve provides the normal operating features of the R/S CK-2 suction stop valve and features a built-in failsafe to close the valve until pressure is equalized in the event of a power loss.Gas Powered Suction Stop Valve- CK-5 Parker NAThe CK-5 gas-powered suction stop valve provides the normal operating features of the R/S CK-2 suction stop valve and features a built-in failsafe to close the valve until pressure is equalized in the event of a power loss.Select attributes to refine your product search.Gas Powered Suction Stop Valve- CK-6D Parker NAThe CK-6D is a suction stop valve for hot gas defrost applications.This normally open valve features dual solenoids for equalization and a pressure regulator to prevent the valve from opening during defrost in the event of a power loss Select attributes to refine your product search.

Gas Powered Suction Stop Valve- Pilot Assemblies Parker NA

Markets Industrial Refrigeration Commercial Refrigeration Features and Benefits Low Pressure Drop for Low Temperature Operation Suitable to -50°C (-60°F) Maximum Rated Pressure (MRP) 27.6 bar (400 PSIG) Requires no minimum pressure drop to open Use on S9A and S9W Gas Powered Suction Stop Valves Application Use in viscous oil conditions Vertical pipelines Where very lowGas Powered Suction Stop Valve- S9A-S9W Parker NAA lapped seat at the top of the piston prevents the condenser gas from leaking around the piston to the compressor suction side of the valve.A twin Pilot Solenoid Valve assembly serves to admit condenser gas pressure to the piston for opening and to bleed this gas pressure to the suction line for valve closing.Gas Powered Suction Stop Valves- Ck-2 - Clark Johnson CoJun 09,2019·These CK-2 Gas Powered Suction Stop Valves are used on low temperature applications to positively close suction lines and both liquid legs and gas returns on flooded evaporators.Overview; Specifications; Overview; These piston type,gas pressure powered,normally open,heavy duty,cast iron bodied valves are built with control valve precision

Gas Powered Suction Stop Valves- Ck-2 Parker NA

These CK-2 Gas Powered Suction Stop Valves are used on low temperature applications to positively close suction lines and both liquid legs and gas returns on flooded evaporators.Gas-Powered Valves Hansen TechnologiesHCK5 Gas-Powered Suction Stop Valve These heavy-duty,durable,ductile iron or cast steel body,gas-powered suction stop valves are designed to control the flow of refrigerant in large industrial and commercial applications.HCK2 Gas-Powered Suction Stop Valve HansenMar 09,2016·These heavy-duty,flanged,gas-powered suction stop valves are designed to control the flow of refrigerant in large industrial and commercial applications.They remain normally open via a spring and require no pressure drop to operate.

HCK5 Gas-Powered Suction Stop Valve Hansen

Mar 09,2016·These heavy-duty,durable,ductile iron or cast steel body,gas-powered suction stop valves are designed to control the flow of refrigerant in large industrial and commercial applications.They remain normally open via a spring and require no pressure drop to operate.HCK5D 2-Step Gas-Powered Suction Stop Valve Hansen Mar 09,2016·These heavy-duty,flanged,gas-powered,2-step suction stop valves are designed to control the flow of refrigerant in large industrial and commercial refrigeration systems.They remain normally open via a spring and require no pressure drop to operate.A single pilot solenoid valve is required to control a higher pressure refrigerant gas which Hansen HCK5w/6,6 (150MM) Gas Powered Suction StopThese heavy-duty,durable,ductile iron or cast steel body,gas-powered suction stop valves are designed to control the flow of refrigerant in large industrial and commercial applications.Hansen HCK5w/ 6,6 (150MM) Gas Powered Suction Stop Valve

Images of Gas Powered Suction Stop Valve

imagesGAS POWERED SUCTION STOP VALVE - Parker HannifinGAS POWERED SUCTION STOP VALVE Type S9A Port Size 50-100mm (2 - 4) FOR AMMONIA,R12,R22,R502 AND OTHER COMMON REFRIGERANTS FEATURES Low Pressure Drop for Low Temperature Operation Suitable to -50°C (-60°F) Can Be Installed in Vertical or Horizontal Position Manual Opening Feature 27.6 bar (400 PSIG) Maximum Rated Pressure (MRP)Location 3475 Old Maysville Road Commerce,GA 30529 USAGAS POWERED SUCTION STOP VALVEGAS POWERED SUCTION STOP VALVE Type CK-5 Port Size 32mm to 150mm (1¼ - 6) Suitable For Ammonia,R22,R502,R134a,R404a and Other Common Refrigerants FEATURES Normally Open Low Pressure Drop Manual Opening Stem Integrated Pilot Solenoid on 32mm to 100mm (1-1/4 to 4) Sizes Use in Vertical or Horizontal LineMVP Hansen TechnologiesThese offer the enhanced control functionality of a gas-powered two-step suction stop valve,a brand new feature for MVP valves.Ships pretested and assembled for quick and easy installation,requiring only two welds to complete most valve station applications.No disassembly is required.

Parker CK2 Gas Powered Suction Stop Valves 32-150mm (1

Parker CK2 Gas Powered Suction Stop Valves 32-150mm (1-1/4-6) Parker CK2 Gas Powered Suction Stop Valves 32-150mm (1-1/4-6) Part Kits.ITEM NO.DESCRIPTION.OTY.32mm (1-1/4) 40mm (1-5/8) 50mm (2) 65mm (2-1/2) 75mm (3) 100mm (4) 125mm (5) 150mm (6) 5 4.PISTON PLUG ASM COVERGASKET.1 1 4.5.PISTON PLUG KIT 201205.201140 Related searches for gas powered suction stop valvewater suction valvesuction check valvesuction valve pumpcompressor suction valvesuction valve functioncompressor suction service valvesuction valve hvacnatural gas stop valve12345NextSUCTION STOP VALVE GAS POWERED - Parker HannifinThe purpose of the CK-5 gas-powered suction stop valve is to provide the normal operating features of the R/S CK-2 stop valve.In addition,this unique control valve incorporates a built-in mechanical fail-safe feature which prevents the undesirable effects of an immediate opening of the valve in the

Solenoid Valves- S4A Type - Clark Johnson Co

May 31,2019·Gas Powered Suction Stop Valve- Pilot Assemblies.Gas Powered Suction Stop Valve- Pilot Assemblies.Solenoid Valves S8F and S6N.Solenoid Valves S8F and S6N.Solenoid Valves- S5A,S5AE.Solenoid Valves- S5A,S5AE.Solenoid 3-Way Heat Reclaim Valve.Solenoid 3-Way Heat Reclaim Valve.Specifiations,Applications,Service Instructions Parts GAS-POWERED,2-STEP SUCTION STOP VALVE 1-1/2 THRU 4 PORT (40 MM THRU 100 MM) Bulletin C429a MAY 2011 HCK5D 2-Step Gas-Powered Suction Stop Valve Flanged 1-1/2 thru 4 SW,WN,ODS for refrigerants INTRODUCTION These heavy-duty,flanged,gas-powered,2-step suction stop valves are designed to control the flowSpecifications,Applications,Service Instructions Parts GAS-POWERED SUCTION STOP VALVES 1-1/4 THRU 6 PORT (32 mm THRU 150 mm) Bulletin C409e AUG 2006 Flanged 1-1/4 thru 4 FPT,SW,WN,ODS for refrigerants HCK2 Gas-Powered Suction Stop Valve INTRODUCTION These heavy-duty,flanged,gas-powered suction stop valves are designed to control the flow of refrigerant

Specifications,Applications,Service Instructions Parts

GAS-POWERED SUCTION STOP VALVES 1-1/4 THRU 6 PORT (32 mm THRU 150 mm) Bulletin C409e FEB 2019 Flanged 1-1/4 thru 4 FPT,SW,WN,ODS for refrigerants HCK2 Gas-Powered Suction Stop Valve INTRODUCTION These heavy-duty,flanged,gas-powered suction stop valves are designed to control the flow of refrigerantSpecifications,Applications,Service Instructions Parts GAS-POWERED,2-STEP SUCTION STOP VALVE 1-1/2 THRU 4 PORT (40 mm THRU 100 mm) Bulletin C429a mAY 2011 HCK5D 2-Step Gas-Powered Suction Stop Valve Flanged 1-1/2 thru 4 SW,WN,ODS for refrigerants INTRODUCTION These heavy-duty,flanged,gas-powered,2-step suction stop valves are designed to control the flow

Comments

Leave a Message